Herunterladen Inhalt Inhalt Diese Seite drucken

Installation Instructions; Flow Diagram - HANSGROHE Raindance Select S 120 Eco U'S Puro 65 26632000 Gebrauchsanleitung, Montageanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Safety Notes
• Gloves should be worn during installation to prevent
crushing and cutting injuries.
• The product may only be used for bathing, hygienic
and body cleaning purposes.
• The product may not be used as a holding handle. A
separate handle must be installed.
• Shower hoses are only suitable for a connection from
the shower to the fitting. Never fit a shut-off device
between the fitting and the hose.

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• Thermostatic mixer: Operation / Assembly see en-
closed brochure
• Where the contractor mounts the product, he should
ensure that the entire area of the wall to which the
mounting plate is to be fitted, is flat (no projecting
joints or tiles sticking out), that the structure of the wall
is suitable for the installation of the product and has
no weak points. The enclosed screws and dowels are
only suitable for concrete. For another wall construc-
tions the manufacturer's indications of the dowel
manufacturer have to be taken into account.
• Optimal functioning is only guaranteed with the com-
bination of Hansgrohe hand showers and Hansgrohe
shower hoses.
• The mesh washer must be insert to protect the over-
head shower against incoming dirt by pipework. In-
coming dirt leads to defects or/and can damage parts
of the shower; such caused faults voids all liability and
guarantee claims.
• For removal of the installed EcoSmart (flow limiter)
from the shower, the pressure must be lower than
0.2 MPa. With a pressure of more than 0.2 MPa, the
EcoSmart must not be removed.
4
English
Technical Data
Operating pressure:
Recommended operating pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Thermal disinfection:
The product is exclusively designed for drinking water!
Symbol description
Assembly see page 31
Do not use silicone containing acetic acid!
Operation (see page 33)
Dimensions (see page 34)

Flow diagram

(see page 35)
Spare parts (see page 36)
XXX = Colors
000 = chrome plated
400 = white/chrome plated
Special accessories (order as an
extra)
tile-matching-disk chrome plated
#97450000 (see page 32)
Test certificate (see page 40)
Cleaning (see enclosed brochure)
max. 0,6 MPa
0,2 - 0,4 MPa
max. 60°C
max. 70°C / 4 min

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis