Herunterladen Inhalt Inhalt Diese Seite drucken

Flow Diagram - HANSGROHE Ecostat Select 13141000 Gebrauchsanleitung, Montageanleitung

Vorschau ausblenden Andere Handbücher für Ecostat Select 13141000:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Flow diagram

(see page 69)
Shower
Bath tub
Spare parts (see page 70)
Fault
Insuicient water
Crosslow, hot water being forced
into cold water pipe, or vice versa,
when mixer is closed
Spout temperature does not cor-
respond with temperature set
Temperature regulation not possible
Shower or spout dripping
Instantaneous heater didn't work
with thermostat
English
Cause
Supply pressure inadequate
Filters are dirty
Shower ilter seal dirty
Backlow preventers dirty or leak-
ing
Thermostat has not been adjusted
Hot water temperature too low
thermo cartridge calciied
Dirt or sedimentation on valve seat,
shut-of unit damaged
Ecostop safety set removed.
Flow limiter in handshower isn't
removed
Filters are dirty
Non return valve hasn't moved
back
Assembly see page 60
Cleaning (see enclosed brochure)
Remedy
Check water pressure (If a pump
has been installed check to see if
the pump is working).
Clean ilter in front of the mixer
and on the MTC-thermo cartridge
Clean ilter seal between shower
and hose
Clean backlow preventers, ex-
change if necessary
Adjust thermostat
Increase hot water temperature to
42 ºC to 65 ºC
Exchange thermo cartridge
Clean or exchange shut-of unit
Remove Ecostop safety set
(95771000)
Remove low limiter
Clean the ilter / exchange ilter
Exchange non return valves


Quicklinks ausblenden: