Safety Notes
Gloves should be worn during installation to prevent crushing and cutting
injuries.
The arm of the shower head is intended only to hold the shower head. Do not
load it down with other objects!
Children as well as adults with physical, mental and/or sensoric impairments
must not use this product without proper supervision. Persons under the influ-
ence of alcohol or drugs are prohibited from using this product.
Do not allow the streams of the shower touch sensitive body parts (such as your
eyes). An adequate distance must be kept between the shower and you.
The product may not be used as a holding handle. A separate handle must be
installed.
The shower system may only be used for bathing, hygienic and body cleaning
purposes.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• The pipes and the fixture must be installed, flushed and tested as per the applica-
ble standards.
• The plumbing codes applicable in the respective countries must be oberserved.
• The installation dimensions stated in these installation instructions are ideal for
people of approximately 1800 mm in body height. The dimensions can be
altered if required. In this case, pay attention to the fact that a change of instal-
lation height will also change the minimum height, and that the altered mounting
dimensions must be taken into consideration.
• Where the contractor mounts the product, he should ensure that the entire area of
the wall to which the mounting plate is to be fitted, is flat (no projecting joints or
tiles sticking out), that the structure of the wall is suitable for the installation of the
product and has no weak points. The enclosed screws and dowels are only suit-
able for concrete. For another wall constructions the manufacturer's indications of
the dowel manufacturer have to be taken into account.
• The mesh washer must be insert to protect the overhead shower against incoming
dirt by pipework. Incoming dirt leads to defects or/and can damage parts of the
shower; such caused faults voids all liability and guarantee claims.
• If required, the bottom part of the pipe between the fixture and the shower head
can be shortened with a fine-toothed saw.
• In case of problems with the continuous water heater or of greatly varying water
pressures, you must install the water limiter (comprised in the delivery, article
number 97510000) in the cold water supply.
Fault
Insufficient water
Crossflow, hot water being forced into cold water pipe,
or vice versa, when mixer is closed
Spout temperature does not correspond with tempera-
ture set
Temperature regulation not possible
Instantaneous heater didn't work with thermostat
4
English
Cause
- Supply pressure inadequate
- Filters are dirty (#96922000)
- Shower filter seal dirty
- Backflow preventers dirty or leaking
- Thermostat has not been adjusted
- Hot water temperature too low
- thermo cartridge calcified
- Flow limiter in handshower isn't removed
- Filters are dirty
- check valve hasn't moved back
Assembly see page 31

Technical Data

Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Centre distance:
Connections G 1/2:
Thermal disinfection:
Safety against backflow
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Safety Function (see page 34)
The desired maximum temperature for example max. 42º C can be pre-
set thanks to the safety function.
Adjustment (see page 34)
After the installation, the output temperature of the fitting must be tested
and set to the temperate desired by the customer.
Maintenance (see page 35)
• To guarantee the smooth running of the thermostat, it is necessary
from time to time to turn the thermostat from total hot to total cold.
• The mixer is equipped with check valves. The check valves must be
checked regularly according to DIN EN 1717 in accordance with
national or regional regulations (at least once a year).
Dimensions (see page 37)
Flow diagram (see page 37)
overhead shower
Hand shower
Operation (see page 33)
Cleaning (see page 36) and enclosed brochure
Spare parts (see page 38)
Test certificate (see page 40)
Special accessories (order as an extra)
tile-matching-disk chrome plated #98681000
Remedy
- Check water pressure (If a pump has been installed
check to see if the pump is working).
- Clean filter in front of the mixer and on the MTC-
thermo cartridge (#96922000)
- Clean filter seal between shower and hose
- Clean backflow preventers, exchange if necessary
- Adjust thermostat
- Increase hot water temperature to 42 ºC to 65 ºC
- Exchange thermo cartridge
- Remove flow limiter
- Clean the filter / exchange filter
- Exchange check valves
max. 1 MPa
0,25 - 0,5 MPa
1,6 MPa
max. 80°C
65°C
150 ± 12 mm
cold right - hot left
max. 70°C / 4 min