Prior to installation
Safety notes
Protection against scalding
It is recommended that near points of discharge
with particular sensitivity to the outlet temperature
(hospitals, schools, nursing and retirement homes)
thermostatic devices should be installed which can limit
the water temperature to 43 °C. The product includes an
appropriate temperature end stop. It is generally
recommended that the temperature of shower-systems
should not exceed 38 °C in nurseries and specific areas
of care centres. Use Grohtherm Special thermostats with
special handle to facilitate thermal disinfection and
appropriate safety end stop. Applicable standards (e. g.
EN 806-2) and technical regulations for drinking water
must be observed.
This GROHE fitting can be used in conjunction with
a pressurised storage heater or an instantaneous heater.
Operation with unpressurised storage heaters
( = displacement water heaters) is not possible.
To ensure correct operation of the fitting, the flow
pressure should be between 1 and 5 bar.
It is recommendable to install a pressure-reducing valve
in the case of higher flow pressures.
In the case of new installations, flush the cold
and hot water lines thoroughly until the water is
completely free of contamination before and after
installation. Otherwise these residues remaining
in the lines may block the fitting and contaminate
the drinking water.
Make sure that you do not damage the fitting
surfaces with the tool during installation. For this
reason, always use toothed pliers.
7
Installation, Pages 2 + 3
The cold water supply must be connected on the
right, hot water supply on the left.
If you have reversed the fitting connections (hot on right –
cold on left), you can correct this by means of the
thermostatic compact cartridge (47 175) available
as a special accessory, see Page 1.
-
= Figure number
1
c
Note the necessary installation dimensions.
1
Apply sealing compound to the 1/2" threads of the
2
S-unions. Use a suitable sealing compound for this
purpose (available in specialist shops).
Screw the S-unions horizontally into the supply pipes
3
at intervals of 150mm.
Fit escutcheons A onto the S-unions.
4
Check that dirt strainers C are inserted correctly.
Screw the union nuts on the fitting onto the S-unions.
Open the cold and hot water supply and check
the connections for watertightness.
Mark the drill hole for the shower rail and drill the hole.
5
Insert wall plug F. Screw mounting E to the wall with
6
screw F1, using seal E1.
Insert shower rail D into the housing. Push bracket H
7
onto mounting E. Align shower rail D and secure
using set screw H1.
The shower rail must not be cut to length.
Push shower arm I onto shower rail connection D
8
from above and secure using set screw I1.
Insert filter J1 and seal J2 in head shower J.
9
Next, screw head shower J onto shower arm I.
Screw taper nut K1 of shower hose K onto hand
0
shower L using filter L1.
Screw nut K2 of shower hose K onto the fitting.
GB