Setting the parameters wind and inclination
7.3. Initial operation – Test under normal conditions
After the values are set to the individual requested parameters, it must be ensured that
the awning can be moved normally during daily operation.
Step 1
Push the DOWN button at the hand-held transmitter for 1 second.
During extending the awning movements and vibrations are generated at the drop
file.
• Awning extends to the lower end limit switch without any problems
Adjustment of the sensitivity is so far in order.
• Awning retracts automatically during extending
Sensitivity must be corrected (see 7.2.).

7.4. Changing the parameters wind and inclination angle detection

If the set parameters on the commeo Wind Sensor will be changed, the corresponding
tests (initial operation) must be repeated in order to ensure the requested functionality.