Device components

2.7. Reed contact

The Reed contact in the cover conduces to recognize if the housing of the commeo
Wind Sensor is closed or opened. In the closed condition the in the base plate
in corporated magnet is positioned above the reed contact. The commeo Wind Sensor
is in operation.
When the housing is opened the value of the wind sensitivity and the inclination angle
detection can be set. The movement through the handling will not be analyzed by the
commeo Wind Sensor and does not lead to the retraction of the awning.

2.8. LED display

The LED is used for the visual display of transmitter and status conditions of the Wind
Sensor. The following displays are possible when the cover is opened:
LED color
red
orange, then red
orange
orange, then green 2 seconds
green
Display
flashes
2 seconds
flashes
flashes 2 ×
25
Definition
Battery voltage < 2.4 Volt, indication of
low battery
Re-program command was sent
Test mode
Sensor sends a driving command or a
command to program
Batteries have been inserted