Place of operation
• operate indoors and outdoors
For outdoor applications, the product must be located or protected so that no
dripping water can enter. We recommend installation in under a hood and in a control cabinet,
respectively, or in a housing.
Installation location
• The device is installed directly on to the gas tank
For installation in a dome, we recommend:
Installation of ventilation set (Part No. 02 063 17).
Prevents water getting into the pressure regulator.

INAPPROPRIATE USE

All uses exceeding the concept of intended use:
• e.g. operation using different media, pressures
• use of gases in the liquid phase
• installation against the flow direction
• changes to the product or parts of the product

USER QUALIFICATION

This product may be installed only by qualified experts. These are personnel who are familiar
with setting up, installing, starting up, operating and maintaining this product.
"Equipment and systems requiring supervision may be operated only by persons aged at
least 18, who are physically capable and who have the necessary specialist knowledge or
who have been instructed by a competent person. Instruction at regular intervals, but at least
once per year, is recommended."

ADVANTAGES AND EQUIPMENT

Filter screen in the inlet connection of the pressure regulator
LPG may contain foreign matter, such as dirt particles. Over a certain size, these particles are
trapped in the filter screen in the inlet connection. If the LPG is not filtered, wear and tear of
the LPG system is increased up to complete failure. See TROUBLESHOOTING.
Pressure relief valve (PRV) option
The pressure relief valve (PRV) is an automatic safety device with limited flow that is installed
in the pressure regulator to protect connected devices against inadmissible high pressures. If
there is inadmissible high pressure at the outlet side, for example due to high temperatures,
the PRV opens and relieves the excess pressure through the breather. When the pressure
falls, the PRV closes again automatically.
A connection to the open air must be created if a pressure regulator with PRV is to be
operated indoors, inside a housing or in any other areas that could be at risk.
"PRV" is marked on the type label of the pressure regulator.
Optional pressure gauge
The product can be equipped with a pressure gauge to show the outlet pressure.
Optional protective membrane
The product can be equipped with a protective membrane to prevent the regulator