Gas phase
Temperature
Air
20 °C (68 °F)
200 °C (392 °F)
400 °C (752 °F)
Hydrogen
20 °C (68 °F)
200 °C (392 °F)
400 °C (752 °F)
Steam (saturated
100 °C (212 °F)
steam)
180 °C (356 °F)
264 °C (507 °F)
366 °C (691 °F)
Characteristics and performance data
Measuring cycle time
Step response time
8)
Ambient conditions
Ambient, storage and transport tempera-
ture

Process conditions

always applies.
range is < 1 %.
Process pressure
nominal pressure stage
PPS GF 40
FKM (SHS FPM 70C3 GLT)
EPDM (A+P 75.5/KW75F)
Time span after a sudden measuring distance change by max. 0.5 m in liquid applications, max 2 m with bulk
8)
1 bar (14.5 psig)
10 bar (145 psig)
0 %
0.22 %
-0.01 %
0.13 %
-0.02 %
0.08 %
-0.01 %
0.1 %
-0.02 %
0.05 %
-0.02 %
0.03 %
0.26 %
-
0.17 %
2.1 %
0.12 %
1.44 %
0.07 %
1.01 %
< 500 ms
1 m/min
Products with high dielectric constant (>10) up to 5 m/
min.
-40 ... +80 °C (-40 ... +176 °F)
-1 ... 6 bar/-100 ... 600 kPa (-14.5 ... 87 psi), depending
-1 ... +40 bar/-100 ... +4000 kPa (-14.5 ... +580 psig),
see supplementary instructions manual "Flanges ac-
cording to DIN-EN-ASME-JIS"
-40 ... +80 °C (-40 ... +176 °F)
-40 ... +150 °C (-40 ... +302 °F)
-40 ... +150 °C (-40 ... +302 °F)
11 Supplement
Pressure
50 bar (725 psig)
1.2 %
0.74 %
0.52 %
0.61 %
0.37 %
0.25 %
-
-
9.2 %
5.7 %
73