Steps to be taken in case of blockage

ATTENTION!
When there is a blockage or fault, water sources which drain into the unit should not be used.
/
Disconnect from electrical supply by withdrawing plug and ensure that it cannot be inadvertantly
reconnected.
/
Remove cap seal (1) from tank.
/
Insert a screwdriver or electrical drill and clear a possible blockage of the cutting system by
manually rotating the rotorshaft.
If rotating the rotorshaft fails to clear the blockage then the complete motor/pumping unit must be
removed from the tank for inspection and the blockage cleared by hand (see page 42, fig. 9).
ATTENTION!
Care must be taken when handling the motor/pumping unit as there is a danger of injury from the cutting
tool in the hydraulic system.