Herunterladen Inhalt Inhalt Diese Seite drucken

Waeco SinePower SP700 Bedienungsanleitung Seite 35

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
_MSK.book Seite 35 Montag, 26. Februar 2007 10:15 10
SinePower
"Status" LED (6 5, page 4)
The "Status" LED shows the operating condition of the inverter.
Display
Green, permanently lit
Green, slowly flashing
Red, quickly flashing
Red, slowly flashing
Red, occasionally flashing
Red, permanently lit
Malfunctions (see the "Rectifying faults" chapter on page 37)
The inverter switches off if:
The battery voltage falls below 10.5 V / 21 V
The battery voltage rises above 15.3 V / 30.6 V
The inverter overheats
Note
The individual cut-off values can be found in the "Technical data"
chapter on page 38.
➤ If this happens, shut down the inverter with the main switch (6 2, page 4).
➤ Check that the inverter is sufficiently ventilated and that the ventilation
grilles are unimpeded.
➤ Wait 5 – 10 minutes and switch the inverter on again without any con-
sumer units.
When operating the inverter at a high load for lengthy periods, it is advisable
to start the engine in order to recharge the vehicle battery.
Using the inverter
Input voltage
Normal mode
Energy-saving mode
Input voltage too high
Input voltage too low
Overheating
Excessive load
35

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis