Herunterladen Inhalt Inhalt Diese Seite drucken

Installation And Connection; Protective Measures - Oase AquaMax Eco Expert 21000 Gebrauchsanleitung

Vorschau ausblenden Andere Handbücher für AquaMax Eco Expert 21000:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
- EN -

Installation and connection

Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.

Protective measures:

 Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water:
Isolate the units and installations (switch off and disconnect from the power supply) before reaching into
the water.
 Isolate the unit before starting any work.
 Secure the unit to prevent unintentional switching on.
Attention! Dangerous electrical voltage.
Possible consequences: Death or serious injuries due to operation of this unit in a swimming pond.
Protective measures:
 Do NOT use this unit in a swimming pond.
 Adhere to national and regional regulations.
Operating the unit in the pond
 C
 Never operate the pump in a swimming pond.
 Only operate the pump when it is below the water surface level.
 Only operate the pump with the filter basket fitted.
 Ensure that the pump is in a secure and stable position.
 The position of the pump outlet can be changed. The pump casing has to be turned to achieve a different position.
( Turning the pump casing)
Note!
If the pump is used for conveying excessively soiled water, the impeller unit will be subject to increased wear
and will require earlier replacement.
Remedy:
 Thoroughly clean the pond or pool before installing the pump.
 Install the pump approx. 200 mm above the floor of the pond to avoid excessively soiled water from being
drawn into the pump.
How to proceed:
 D
1. Screw the stepped hose adapter including union nut and sealing ring to the outlet.
2. Connect the hose with the stepped hose adapter and secure with a hose clip.
Install the unit at a dry place
 E
 Swimming pond or pool that may be accessed by people.
– Install the unit at least 2 m away from the water.
 Do not expose the unit to direct sunlight.
 Ensure that the pump is in a secure and stable position.
 The position of the pump outlet can be changed. The pump casing has to be turned to achieve a different position.
( Turning the pump casing)
16