Only qualified contractors should carry out installation, commis-
sioning, maintenance and repair of the appliance.
7.1

general safety instructions

We guarantee trouble-free operation and operational reliability
only if the original accessories and spare parts intended for the
appliance are used.
7.2

instructions, standards and regulations

Note
Observe all applicable national and regional regulations
and instructions.
8.

appliance description

8.1

standard delivery

Delivered with the appliance:
- Plastic cap
8.2

accessories

8.2.1 required accessories
Depending on the static pressure, safety assemblies and pressure
reducing valves are available. These type-tested safety assemblies
protect the appliance against unacceptable excess pressure.

8.2.2 Further accessories

- Thermometer
- Segmented anode
9.

Preparations

9.1

installation location

Always install the appliance in a room free from the risk of frost
and near the draw-off point, and secure the appliance to the floor.
9.2

Handling

Damage to the appliance and environment
!
We recommend removing the cylinder casing for trans-
portation to the installation location to prevent it from
becoming dirty or damaged (see chapter "Installation /
Fitting the cylinder casing and DHW circulation line if

required").

WWW.stieBel-eltron.com

10. mounting

10.1 Fitting the cylinder casing and dHw circulation
line if required
Note
Fit the cylinder casing before making the water connec-
tion and, if necessary, before installing the DHW circula-
tion line.
A DHW circulation line can be fitted to the "DHW circulation"
connection (see chapter "Specification / Dimensions and connec-
tions"). Alternatively, the "DHW circulation" connection can be
used to connect a thermometer.
dismantling
f Pull off the temperature selector.
f
f Remove the screws at the bottom of the control panel cover.
f
f Remove the control panel cover and cable grommet.
f
f Undo the zip fastener and remove the cylinder casing.
f
mounting
f Pull the cylinder casing over the appliance and close the zip
f
fastener at the front.
f Fit the cable grommet and control panel cover.
f
f Push on the temperature selector.
f
f If you are connecting a DHW circulation line, cut an aperture
f
for this in the cylinder casing in the area of the connection
(indentation in the foam).
f Remove the thermal insulation around the "DHW circulation"
f
connection.
f Route the DHW circulation line through the aperture in the
f
cylinder casing and fit the DHW circulation line.
f Insulate the "DHW circulation" connection.
f
hstp |
19