We therefore recommend that you first note down your required settings in the check
boxes beside the menu structure and then do the programming in one go. This makes
programming easier and avoids errors.
All programming settings are stored in a non-volatile memory and remain stored even
if the controller was disconnected from the battery.
If you want to reset the controller to the factory settings, choose Programming Menu 9.
Programming Lock-out
By pushing the button for 8 sec in normal operation mode the programming lock-out
is activated to prevent any accidental settings change.
Another 8 sec push releases the lock-out.
General Safety and Usage Recommendations
Intended Use
The charge regulator is intended for use in photovoltaic systems with 24 V or 48 V nominal
voltage. It shall be used with vented or sealed (VRLA) lead acid batteries only.
Safety Recommendations
Batteries store a large amount of energy. Never short circuit a battery under all
circumstances. We recommend connecting a fuse (slow acting type, according to the
nominal regulator current) directly to the battery terminal.