EN
WARNING: The combination of different error conditions may cause damage to the controller.
Always remove an error before you continue connecting the controller!

Error Description

Error condition
Loads are not
supplied
Display
Reason
Battery is low
Overcurrent /
Short circuit of
loads
Controller is
thermally
overloaded and has
disconnected the
loads.
Battery voltage too
high
(>31.0 / 62.0 V)
Battery wires or
battery fuse
damaged, battery
has high resistance
Remedy
Load will reconnect as
soon as battery is
recharged.
Switch off all loads.
Remove short circuit.
Controller will switch on
load automatically after
max 1 minute.
Check proper ventilation
of controller.
After cooling down the
loads are reconnected
automatically.
Check if other sources
overcharge the battery. If
not, controller is
damaged.
Check battery wires,
fuses and battery.
40