Safety Features

The controller is protected against wrong installation or use:
Battery connected
with correct polarity
Battery connected
with wrong polarity
Reverse polarity
Short circuit
Overcurrent
Thermal overload
No connection
Reverse current
Overvoltage
Undervoltage
At the solar
terminal
Unrestricted
Unrestricted
Yes, not at 24V
system voltage.
Acoustic Warning
Unrestricted
Controller limits
current.
Controller is
electronically
protected.
Unrestricted
Unrestricted
Max.90 V
Normal operation Controller switches
39
At the battery
terminal
Normal operation
Unrestricted.
Acoustic Warning
Yes, if only the
battery is
connected.
Unrestricted.
CAUTION: Battery
must be protected
by fuse.
-------
-------
Unrestricted
-------
Max. 80 V
off load terminal.
At the load
terminal
Unrestricted
Unrestricted
Load output is
protected, but loads
might be damaged.
Unrestricted
Controller switches
off load terminal.
Controller switches
off load terminal.
Unrestricted
-------
Controller switches
off load terminal.
Controller switches
off load terminal.