Reconfiguring the BIOS Setup
If the battery replacement takes longer than 30 seconds, the configuration data of the device will be lost. You will have to
reconfigure the BIOS setup in this case.
7

Technical specifications

General technical specifications
Order numbers
Dimensions
Weight
Supply voltage (DC)
Brief power failure
according to Namur
Maximum power consumption
Noise emission
Degree of protection
Safety
Protection class
Safety specifications
Electromagnetic compatibility (EMC)
Emitted interference
Noise immunity:
Mains borne disturbance variables on supply lines
Noise immunity on signal lines
Immunity to discharges of static electricity
Immunity to RF interference
Magnetic field
The generation of the 24 VDC supply voltage by the line-side power supply must be made as functional extra-low
1
voltage with safe electrical isolation according to
IEC 60364-4-41 or as SELV in conformity with IEC/UL/EN/DIN-EN 60950-1 and LPS / NEC Class 2.
Climatic Conditions
Temperature
- During operation
- During storage/shipping
- Gradient
SCALANCE WLC711
A5E03740572-05, 04/2016
see the order documents
262x142x47 (WxHxD in mm)
Approximately 2 kg
24 VDC
(19.2 to 28.8 V)
1
min. 15 ms (at 20.4 V)
Max. 10 events per hour; min. 1 s recovery time
4 A (at 24 V)
<40dB (A) to DIN 45635-1
IP 20 to IEC 60529
Protection class I to IEC 61140
EN 60950-1; UL 60950-1; CAN/CSA-C22.2 No. 60950-1; UL 508;
CAN/CSA-C22.2 No. 142 or CAN/CSA-C22.2 No.14-05
EN 61000-6-3 , EN 61000-6-4 , CISPR22:2004 Class B;
FCC Class A
+/- 2 kV to IEC 61000-4-4; Burst
+/-1 kV to IEC 61000-4-5; surge symmetric
+/- 2 kV to IEC 61000-4-5; Surge asymmetric
± -1 kV to IEC 61000-4-4; Burst; Length < 3 m
± /-2 kV to IEC 61000-4-4; Burst; length > 3 m
± /-2 kV to IEC 61000-4-5; Surge; length > 30 m
+/-6 kV contact discharge according to IEC 61000-4-2
-8 kV air discharge according to IEC 61000-4-2
10 V/m 80 – 1000 MHz and 1.4 - 2 GHz, 80% AM to IEC 61000-4-
3
1 V/m 2 - 2.7 GHz, 80% AM to IEC 61000-4-3
10 V 10 KHz – 80 MHz, 80% AM to IEC 61000-4-6
100 A/m rms at 50/60 Hz according to IEC 61000-4-8
Tested to IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-14
Horizontal installation:
+5 to +40 °C
Vertical installation / book mounting:
+5 to +40 °C
-40°C through +60°C
Operating mode: Max. 10°C/h; Storage: 20°C/h; no condensation