Herunterladen Inhalt Inhalt Diese Seite drucken

Care And Maintenance - CONDTROL XLiner DUO/COMBO 360 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

CROSS
EN
LINE LASER
Check of vertical line
Use a plumb bob as a reference of a vertical line. Place the laser level at
a 1,5m distance from the plumb bob (see Fig. E).
1. Move compensator lock to ON position
plane and align vertical laser line with the low point of plumb bob.
2. If deviation between the laser line and the plumb line exceeds 0.2
mm per 1m of the plumb bob length (for a 2.5m plumb bob deviation
shouldn't exceed 0.5 mm) please contact service center.
E
14
XLiner Duo/Combo 360
user manual
, then switch on vertical
CROSS
EN
LINE LASER

CARE AND MAINTENANCE

Maintenance of the following recommendations will extend the life
of the device:
- Transport and carry the product only with locked compensator.
- Keep the product clean and protected from any bumps, dust and
dampness; do not allow getting moisture, dust or other dirt inside of
the product.
- In case if any moisture goes into the product, remove the batteries
and take it to the service center.
- Do not keep or use the device for a long time at high humidity
conditions.
- Keep the instrument clean and wipe it with a clean and soft cloth.
Mishandling of the following rules can cause electrolite leakage
from the batteries or other damages:
- Remove the batteries from the product if you do not use it for a long
time.
- Do not use different battery types with different charge levels.
- Do not leave discharged batteries in the product.
XLiner Duo/Combo 360
user manual
15

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis