Malfunction
The pump is not delivering,
or the delivered quantity is
insufficient.

WEAR PARTS

Wear parts are excluded from the war-
ranty.
The following components are wear parts
and may only be replaced by the OASE
Service.
Impeller
STORAGE/OVER-WINTERING
The unit is not frost-proof and has to be
removed and put into storage if minus
temperatures are expected.
How to correctly store the unit:
Drain the unit as far as possible, clean
thoroughly and check for damage.

TECHNICAL DATA

ProMax Garden Classic
Rated voltage
Rated frequency
Rated power
Protection type
Cause
The pump is not sufficiently
filled with water.
Pressure line blocked
Suction line blocked
Leak on the suction side
External pre-filter (optional)
clogged
Empty all hoses, pipes and connections
as far as possible.
Thoroughly clean the unit, check it for
damage and replace any damaged
parts.
Store the unit in a dry and frost-free
place.
Do not immerse plugs in water.
DISPOSAL
Do not dispose of this unit with domestic
waste! For disposal purposes, please use
the return system provided. Render the
unit unusable beforehand by cutting the
cables.
V AC
Hz
Max.
W
Remedy
Fill the pump and ensure
that the water does not flow
out on the pressure side.
 Open the water with-
drawal point on the pres-
sure side.
Route the pressure hose
without kinks
Clean the connection on
the suction side and the
suction line
Route the suction hose
without kinks
Eliminate leak on the suc-
tion side
Clean the pre-filter
3000
4500
230
230
50
50
600
900
IP 44
IP 44
DE
EN
FR
NL
ES
PT
IT
DA
NO
SV
FI
HU
PL
CS
SK
SL
HR
RO
BG
UK
RU
CN
13

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Promax garden classic 4500

Inhaltsverzeichnis