Herunterladen Inhalt Inhalt Diese Seite drucken

Nibe SMS 40 Installateurhandbuch Seite 18

Kommunikationsmodul
Vorschau ausblenden Andere Handbücher für SMS 40:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

GB
Command
!opmode
!tluxhw
!reg1
!reg2
!reg3
!reg4
!roomt1
!roomt2
!roomt3
!roomt4
!vacat
!alarm
!vent
*Accessories needed.
Example
To check the selected operating mode, the following SMS message is sent: ?status
To activate "Temporary lux, hot water" for 12 hours, the following SMS message is sent: !tluxhw 12
Both commands are answered with a status message.
18
Parameter
Answer
0/1
?status
0/3/6/12
?status
-10-+10
?status
-10-+10
?status
-10-+10
?status
-10-+10
?status
5-30
?status
5-30
?status
5-30
?status
5-30
?status
1/0
?status
0/1/2/3/4
Description
Change operating mode
Auto/add. heat only
Temporary lux, hot water. 0/3/6/12 hours.
Temperature (offsetting the heat curve in systems without room
sensors)
Temperature (offsetting heat curve in systems without room
sensor), climate systems 2*
Temperature (offsetting heat curve in systems without room
sensor), climate systems 3*
Temperature (offsetting heat curve in systems without room
sensor), climate systems 4*
Temperature (setting the room temperature in systems with
room sensors)
Temperature (setting the room temperature in systems with
room sensors), climate system 2*
Temperature (setting the room temperature in systems with
room sensors), climate system 3*
Temperature (setting the room temperature in systems with
room sensors), climate system 4*
activating/deactivating holiday settings
Resets alarm
Changed fan speed. 0=normal fan speed*