Contact with SMS 40
SMS commands F370/F470/F750/F1145/F1245
SMS 40 sends an SMS in the event of a power cut, when F370/F470/F750/F1145/F1245 starts after a power cut and in
the event of a constant alarm. These messages are only sent to the alarm recipient (menu 5.3.5).
SMS 40 can receive and send the following commands to F370/F470/F750/F1145/F1245:
Command
Answer
?status
opmode: auto/add. heat only
reg1: -10-+10
reg2: -10-+10
reg3: -10-+10
reg4: -10-+10
roomt1: 5-30
roomt2: 5-30
roomt3: 5-30
roomt4: 5-30
tluxhw: on/off
vent: 0/1/2/3/4
vacat: on/off
?comp
status: on/off
number of starts: nn
total operating time: nn
- of which hot water: nn
?temp
flow: nn
return: nn
outd: nn
indoor: nn
calcf:nn
DM: nn
Bin: nn
Bout: nn
hw: nn
*Accessories needed.
Description
Operating status
Temperature (offsetting the heat curve in systems without room sensors)
Temperature (offsetting heat curve in systems without room sensor), climate
systems 2*
Temperature (offsetting heat curve in systems without room sensor), climate
systems 3*
Temperature (offsetting heat curve in systems without room sensor), climate
systems 4*
Temperature (setting the room temperature in systems with room sensors)
Temperature (setting the room temperature in systems with room sensors),
climate system 2*
Temperature (setting the room temperature in systems with room sensors),
climate system 3*
Temperature (setting the room temperature in systems with room sensors),
climate system 4*
Temporary lux (hot water)
Fan speed. 0 = normal fan speed*
Holiday setting
Compressor status
Number of compressor starts
Total run time compressor and immersion heater?
Total run time hot water
Supply temperature
Return temp
Outdoor temperature
Indoor temperature. If the room temperature sensor is not installed/activated,
the following appears -
Calculated flow line temperature
Degree minutes
Incoming brine temperature
Outgoing brine temperature
Hot water temp.
GB