7.7. Washing and sanitizing the components
All of the component parts previously disassembled
(tap, mixer, mixing auger, gasket and bowl) must be
carefully washed and sanitized.
To carry out this procedure correctly proceed as follows:
• Fill a container with detergent and hot water with
a temperature of 50~60°C (122~140°F);
• Wash the disassembled components with the de-
tergent solution;
7.8. Assembling the washed components
All washed and sanitized component parts must be re-assembled with care and then subsequently refitted
to the machine, following the relevant steps.
7.8.1. Assembling the bowl
EN
18
• Rinse with hot water;
• Clean only with warm water and a sanitizing prod-
uct made from sodium hypochlorite diluted in water
to obtain an active chloride concentration of 0.02%;
• Immerse the disassembled component parts in
the sanitizing solution for about 30 minutes;
• Rinse with clean water;
• Clean the bowl lid,(see paragraph 7.11)
• Place the components on a clean surface and dry them.
Warning: make sure that the gasket is correctly as-
sembled.
• Fig. 33 shows a seal correctly assembled; here the
seal perfectly adheres to the bowl edge.
Fig. 33
• Fig. 34 shows a seal which is not correctly assem-
bled; here the seal does not perfectly adhere to the
bowl edge.
Fig. 34
• Fit the bowl back into place firmly downward, after
moistening the seal with water
Fig. 35
DO NOT USE GREASE OR VASELINE.
Warning: make sure that the bowl is correctly fitted
to the machine; an incorrectly fitted bowl will cause
the product to leak out; risk of scalding!
• Fig. 36 shows a bowl correctly assembled; here the
bowl perfectly adhere to the machine edge.
Fig. 36