micro CA-150 Inspection Camera
3' and 6' cable extensions are available to in-
crease the length of your cable up to 30' in
length. To install an extension, first remove
the camera head cable from the display unit
by loosening the knurled knob. Connect the
extension to the handheld as described above
(Figure 5). Connect the keyed end of the cam-
era head cable to the slotted end of the exten-
sion and finger tighten the knurled knob to
hold the connection in place.

Installing An Accessory

The three included accessories, (mirror, hook
and magnet) (Figure 1) all attach to the imager
head the same way.
To connect, hold the imager head as shown in
Figure 6. Slip the semicircle end of the acces -
sory over the flats of the imager head as
shown in Figure 6. Then rotate the accessory
a 1/4 turn so the long arm of the accessory is
extending out as shown (Figure 6).
Flats
Figure 6 - Installing An Accessory
Pre-Operation
Inspection
WARNING
Before each use, inspect your inspec-
tion camera and correct any problems
to reduce the risk of serious injury from
electric shock and other causes and
prevent tool damage.
1. Make sure the unit is OFF.
6
Accessory
1/4 Turn
Figure 7 – Warning Label
10. With dry hands, re-install the battery hold -
2. Remove the battery holder and inspect it
and batteries for signs of dam age. Re -
place batteries if necessary. Do not use
inspection camera if batteries are dam-
aged.
3. Clean any oil, grease or dirt from the e -
quip ment. This aids inspection and helps
prevent the tool from slipping from your
grip.
4. Inspect micro CA-150 Inspection Camera
for any broken, warn, miss ing, misaligned
or binding parts or any condition which
may prevent safe and normal operation.
5. Inspect the camera head lens for conden-
sation. To avoid damaging the unit, do
not use the camera if condensation forms
inside the lens. Let the water evaporate
before using.
6. Inspect the full length of the cable for
cracks or damage. A damaged cable
could allow water to enter the unit and in-
crease the risk of electrical shock.
7 . Check to make sure the connections be-
tween the handheld unit, extension ca-
bles and imager cable are tight. All con-
nections must be properly assembled for
the cable to be water resistant. Con firm
unit is properly assembled.
8. Check that the warning label is present,
firmly attached and readable.
9. If any issues are found during the in-
spection, do not use the inspection cam-
era until it has been properly serviced.
er making sure to fully insert.
11. Press and Hold the Power Button for 2
seconds. A splash screen will appear.
Once the camera is ready, the live view

Werbung