4.3. INSTALLATION STEPS
The operator, base-plate and articulated arm are designed either for right-
hand or left-hand (Fig. 7) installation.
Secure the base-plate to the pilaster, using Ø10 screws and suitable
expansion plugs (Fig. 8), and check it is perfectly horizontal.
Fit the gearmotor unit on the base-plate and secure it with the two screws,
nuts and flexible washers (Fig.8).
The transmission shaft must always face downward.
Assemble the articulated arm and front coupling as shown in Fig. 9.
Fit the straight lever of the articulated arm on the gearmotor shaft and
tighten it with the supplied screw and washer (Fig. 10).
Release the operator (chapter 5.)
Establish the securing position of the front coupling on the leaf, observing
dimension "C" defined previously (chapter 4.2). Check that arm and
coupling are perfectly horizontal.
The coupling may be welded directly onto the leaf (Fig. 11) or screwed
by using the threaded inserts (Fig. 12).
Fig. 11
Fig. 11
In both cases, mark the position of the front fitting and provisionally remove
the coupling from the arm in order to secure it.
After having fastened the front fitting, mount the arm again
Fit the guards on the operator (Fig. 10).
Re-lock the operator (chapter 6.)
Make the electrical connections of the selected electronic appliance,
observing the annexed instructions.
4.4. TEST OF THE AUTOMATION
When you have finished installation, carefully check the operating efficiency
of the automation and of all accessories connected to it, safety devices
in particular.
Hand the "User's Guide" page to the Client, and describe how the operator
should function and be used correctly, stressing the potentially dangerous
areas of the automation.

5. MANUAL OPERATING MODE

Fig. 7
Fig. 7
If the gate has to be operated manually in the event of a power-cut or fault
to the automation, use the release device as follows:
Cut power to the system.
Fit the supplied Allen wrench and turn it by about a half turn until it stops,
in the direction shown in Fig. 13, depending on type of installation.
Move the gate by hand.
6. RESTORING NORMAL OPERATING MODE
To avoid an involuntary pulse from activating the gate during the
Fig. 8
Fig. 8
manoeuvre, before re-locking the operator , switch off power to the
system.
Fit the supplied Allen wrench and turn it by about a half turn until it stops,
in the direction shown in Fig. 13, depending on type of installation.
make sure that the gate cannot be moved manually.
Restore power to the system.
To ensure correct long-term operation and a constant level of safety, we
advise you to generally control the system at least every 6 months. In the
"User's Guide" booklet, there is a form for recording jobs.
Fig. 9
Fig. 9
The User must not in any way attempt to repair or to take direct action
and must solely contact qualified FAAC personnel or FAAC service
centres.
Fig. 10
Fig. 10
Fig. 12
Fig. 12
8
7. MAINTENANCE
8. REPAIRS
Fig. 13
Fig. 13