General
VPA 200/70 is a water heater primarily intended for con-
nection to heat pumps. It is also suitable for use with other
heat sources.
Assembly
Unscrew the water heater from the wooden pallet. Screw
the supplied plastic feet into the stand. The water heater
can be raised by screwing out the length of the feet.
8
7
5
* Distance to hole for entry of cable to submerged tube
(8).
INSTALLATION AND MAINTENANCE INSTRUCTIONS
VPA 200/70
35
10
6
2
4b
1
4a
74
237
357
520
615

Pipe installation

The water heater is only designed for upright installation.
Internal support bushes should be fitted when a plastic
pipe or annealed copper pipe is used. The water heater
must be fitted with the requisite valves, such as a safety
valve, shut-off valve, non-return valve, and vacuum valve.
An overflow pipe must be routed from the safety valve to
a suitable drain. The size of the overflow pipe must be the
same as on the safety valve. Route the overflow pipe from
the safety valve enclosed along its entire length and ensure
that it is frost proof. The outlet of the overflow pipe should
be visible.
Equipment
1.
Cold water inlet, Ø 28 mm
2.
Hot water outlet, Ø 28 mm
4a.
Docking connection, supply pipe (from heat pump*), Ø
28 mm.
4b.
Docking connection, return pipe to heat pump*/radiator
return, Ø 28 mm.
5.
Supply pipe to radiators, Ø 28 mm
6.
Venting, double-jacketed container.
7.
Immersion heater connection, G 50 int. Plugged on deliv-
ery.
8.
Sensor pipe (int. Ø 8 mm, length 85 mm), hot water
heating control
10
Adjustable feet
*or another external heat source
Pressure drop diagram
Primary side
Connection (4a) and (4b).
Pressure drop
kPa
mvp
8
0,8
6
0,6
4
0,4
2
0,2
0
0
0
VPA 200/70
500 1000 1200
2000
2500
GB
8
7
5
Flow
l/h
5

Werbung