Herunterladen Inhalt Inhalt Diese Seite drucken

Specifications; Warnings; User's Responsibility For Ce Compliance - Ramsey Winch RPH 53,3 Originalanleitung

Planetary winch
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

SPECIFICATIONS*

WARNINGS:

THE USER SHALL ENSURE THAT THE OPERATING PERSONNEL ARE GIVEN THE NECESSARY TRAINING.
THE OPERATOR SHALL ALWAYS WORK IN COMPLIANCE WITH THE OPERATING INSTRUCTIONS.
A MOTOR SPOOL (OPEN CENTER) DIRECTIONAL CONTROL VALVE IS REQUIRED FOR BRAKE OPERATION.
CLUTCH MUST BE FULLY ENGAGED BEFORE STARTING THE WINCH.
DO NOT DISENGAGE CLUTCH UNDER LOAD.
STAY OUT FROM UNDER AND AWAY FROM RAISED LOADS.
STAND CLEAR OF ROPE WHILE PULLING. DO NOT TRY TO GUIDE ROPE.
DO NOT USE WINCH TO LIFT, SUPPORT, OR OTHERWISE TRANSPORT PERSONNEL.
A MINIMUM OF 2 WRAPS OF ROPE AROUND THE DRUM BARREL IS NECESSARY TO HOLD THE LOAD.
IN CAR CARRIER APPLICATIONS, AFTER PULLING VEHICLE ON CARRIER, BE SURE TO SECURE VEHICLE TO CARRIER
BED. DO NOT MAINTAIN LOAD ON WINCH ROPE WHILE TRANSPORTING VEHICLE. DO NOT USE WINCH AS A TIEDOWN.
AVOID CONDITIONS WHERE LOAD SHIFTS OR JERKS OCCUR. EXCESSIVE "INCHING" SHALL BE AVOIDED.

USER'S RESPONSIBILITY FOR CE COMPLIANCE

1.
Use only a motor spool (open center) control valve Per Hydraulic System Requirements.
2.
If a remote-operated winch control valve is used, refer to Hydraulic System Requirements for
Emergency Stop components to be installed.
3.
Adjust system relief pressure per Hydraulic System Requirements
4.
Mount winch per Winch Mounting Instructions.
5.
Install 13 mm (.511 inch), grade 1960 wire rope. Maximum rope length of 33 M (110 ft) for
four layers maximum. Attach rope to the drum per Rope Installation Instructions. Hook must
have a safety latch and a minimum breaking strength of 133 kN.
4

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis