DE
3
Filter
4
Emitted light
5
Display text
6
Resolution
7
Exposure mode
8
Exposure time
9
Output rate
10
Webserver lock
Button lock
11
Display rotate
12
Display intensity
13
Display mode
14
28
V
USINT (8bit)
V
BOOL (8bit)
V
SHORT_STRING
(20byte)
V
USINT (8bit)
V
USINT (8bit)
V
UINT (8bit)
V
BOOL (8bit)
BOOL (8bit)
V
V
BOOL (8bit)
V
BOOL (8bit)
V
USINT (8bit)
V
USINT (8bit)
Get/Set
0 = Filter size 1 (dflt)
1 = Filter size 2
2 = Filter size 5
3 = Filter size 10
4 = Filter size 20
5 = Filter size 50
6 = Filter size 100
Get/Set
0 = ON (dflt)
1 = OFF
Get/Set
default: empty (all
zeros) Max length: 19
Characters
Byte 0: Length of string
Get/Set
0 = Resolution high (dflt)
1 = Resolution medium
2 = Resolution low
Get/Set
0 = Mode SCM
1 = Mode LCM
2 = Mode DCM (dflt)
3 = Mode CCM
Get/Set
Max. Exposure Time [ µs ]
Range 100 ... 8000
default: 1000
(Little Endian encoded)
Get/Set
0= normal (Display on)
(dflt)
1= fast
Get/Set
0 = enabled (dflt)
1 = blocked
Get/Set
0 = enabled (dflt)
1= blocked
Get/Set
0 = not rotated (dflt)
1 = rotated
Get/Set
0 = Min
1 = Normal
2 = Max
3 = Power saver mode
4 = Screensaver (dflt)
Get/Set