Start-up
Attention! Sensitive electrical components.
Possible consequence: The unit will be destroyed.
Protective measure: Do not connect the unit to a dimmable power supply.
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
• Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water:
Isolate the units and installations (switch off and disconnect from the power supply) before reaching into
the water.
• Isolate the unit before starting any work.
• Secure the unit to prevent unintentional switching on.
Switching on: Insert the power plug of the transformer into the socket.
• Check the function of the spotlights.
Switching off: Disconnect the transformer power plug.

Remedy of faults

Malfunction
Lamp does not light up
Luminosity decreases
Water inside the spotlight housing
S

Maintenance and cleaning

Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
• Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water:
Isolate the units and installations (switch off and disconnect from the power supply) before reaching into
the water.
• Isolate the unit before starting any work.
• Secure the unit to prevent unintentional switching on.
• Ensure that no moisture can enter the unit.
Cleaning the unit
If necessary, clean the unit with clear water using a soft brush.
Replacing the bulb
How to proceed:
C
1. Remove the protection glass, check for damage and replace if necessary.
2. Remove the defective bulb from the housing.
3. Insert a new bulb (do not touch with your hands, use a cloth or similar).
– Only use 7 Watt halogen lamps. (→ Technical data)
4. Reassemble the unit in the reverse order.
5. Reconnect to the power supply and check the function.
Disposal
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided.
Disable the unit beforehand by cutting off the cables.
8
40419-08-14_GA_LunAqua Micro Eco8 8
Cause
Power supply interrupted
Bulb defective
Lamp glass soiled
The brightness of the bulb reduces as the ope-
rating time increases
Seal defective
Remedy
Check power supply
Replace bulb
Clean
Replace bulb
Check sealing rings and replace, if necessary