Herunterladen Inhalt Inhalt Diese Seite drucken

Installation - Klarstein 10031436 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für 10031436:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Before Installation
• Testrun the unit with proper power supply.
• Refer to the operation instruction section in the Owner's Manual
Operation & Installation. Make sure all the controls operate cor-
rectly then disconnect the power supply of the unit.
• Before installation, please check whether the unit is assembled
with three pieces of rubber pads and square sealing strip.
CAUTION: Moving parts may cause personal injury. Be careful
when test the unit. Do not operate the unit with exterior cover
removed.
Step 1: Installation Location & Installing the Outdoor Unit
Your air conditioner has been designed for use in recreational vehicles. Check the roof of the vehicle to de-
termine if it can support both the roof top unit and the ceiling assembly without additional support. Make
sure the interior ceiling mounting area will not interfere with existing structures. Once the location for your air
conditioner has been determined. A reinforced and framed roof hole opening must be cut (ifthere is no hole)
or you may use existing vent holes.
Case A: If a roof vent is already present in the desired mounting location for the air conditioner, the
following steps must be performed:
1. Remove all screws which secure the roof vent to the vehicle. Remove the vent and any additional trim. Care-
fully remove all chalking from around the opening so the surface is clear.
2. It may be necessary to seal some of the old roof vent mounting screw holes which may fall outside of the
air conditioner basepan gasket.
3. Examine the roof opening size, if the opening is small than 356x356mm, the opening must be enlarged. If
the opening exceeds 356x356mm, a mounting plate (frame) must be fabricated to reduce the opening size
(See picture).
Case B: If there is no roof vent present in the desired mounting location for the air conditioner:
If a roof vent opening is not used,a new opening (see picture) will be cut into the vehicl roof. A matching open-
ing will also have to be cut into the interior vehicle ceiling, be careful when cutting the ceiling opening because
if the ceiling opening is carpeted,snagging could occur.

Installation

34

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis