Contact with SMS 40
SMS 40 sends an SMS in the event of a power cut, when the climate unit starts after a power cut and in the event
of a constant alarm. These messages are only sent to the alarm receiver (menu 4.1.4, menu 5.3.5 if your climate unit
has software version 2041 or earlier).
Caution
The command that is sent to/from SMS 40 must always be written as one word, for example "?solar".
SMS commands for operating information
The following command can be sent to SMS 40 to obtain operating information about your climate unit:
Command
Answer
?status
opmode: auto/add. heat only
reg1: -10–10
reg2: -10–10
reg3: -10–10
reg4: -10–10
roomt1: 5–30
roomt2: 5–30
roomt3: 5–30
roomt4: 5–30
tluxhw: on/off
vent: 0/1/2/3/4
hol: on/off
?comp
status: runs/off
number of starts: nn
total operating time: nn
- of which hot water: nn
?compm/?comps1
status: runs/off
– ?comps8
number of starts: nn
total operating time: nn
- of which hot water: nn
?acomp
heating: nn
hot water: nn
pool: nn
pool 2: nn
?temp
flow: nn
return: nn
outd: nn
SMS 40 | GB
Description
Operating status
Temperature (offsetting the heat curve in systems without room
sensors)
Temperature (offsetting heat curve in systems without room sensor),
1)
climate systems 2
Temperature (offsetting heat curve in systems without room sensor),
1)
climate systems 3
Temperature (offsetting heat curve in systems without room sensor),
1)
climate systems 4
Temperature (setting the room temperature in systems with room
sensors)
Temperature (setting the room temperature in systems with room
sensors), climate system 2
Temperature (setting the room temperature in systems with room
sensors), climate system 3
Temperature (setting the room temperature in systems with room
sensors), climate system 4
Temporary lux (hot water)
Fan speed. 0 = normal fan speed
Holiday setting
2), 3)
Compressor status
Number of compressor starts
Total run time compressor and immersion heater?
2), 3)
Total run time hot water
Compressor status per cooling module (EP14 respectively EP15)
Compressor status =through outdoor section (EB10X)
Number of compressor starts per cooling module (EP14 respectively
4), 7)
EP15)
Total run time, compressor per cooling module (EP14 respectively
4), 7)
EP15)
Total run time, hot water per cooling module (EP14 respectively
4), 7)
EP15)
Number of compressors that produce heat
Number of compressors that charge hot water
Number of compressors that charge pool 1
Number of compressors that charge pool 2
Supply temperature
Return temp
Outdoor temperature
1)
1)
1)
2), 3+1), 4+1)
2), 3)
2), 3)
4), 7)
4), 7)
4+1), 7+1)
4+1), 7+1)
4)
7)
17