Schalt- und steuertafel fur den getriebemotor master 12q
Vorschau ausblenden Andere Handbücher für K123M:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 20
N.B.
The gate must be equipped with the opening and closing safety stops.
When you have completed the installation procedures :
1_ bring the gate to approx. 1 m from the closing travel limit;
2_ set dip-switch no. 8 to ON;
3_ operate the automation using one of the following inputs: A/C, radio control or card button.
4_ the gate must start to close.
N.B.: if it opens, stop the programming procedure by resetting the electric panel (disconnect
the power supply to the panel for at least 5 sec. and set dip-switch no. 8 to OFF); with
the control panel disconnected, exchange the motor supply wires. Restart the procedure
from point 1.
5_ when the gate has closed, after approximately 2 seconds a complete opening manoeuvre is
executed automatically;
6_ when the gate has opened, set dip-switch no. 8 to OFF;
7_ the automation is now ready for operation.
Make the logic adjustments.
N.B.: When any adjusting devices (trimmers or dip-switches) on the control panel are
operated, a complete manoeuvre must be carried out in order for the new settings to
take effect.
TRIMMER
RALL.
slowdown distance adjustment: from about 10 to 100 cm;
T.C.A.
Automatic Closing time adjustment: from about 3 to 255 seconds (see dip-switch no. 1);
FR.
obstacle detection sensitivity adjustment.
NOTE:
by rotating the TRIMMER FR. clockwise the sensitivity of the gearmotor to obstacles
diminishes and therefore the thrust force increases; vice-versa, by rotating it counter-
clockwise, the sensitivity of the gearmotor to obstacles increases and therefore the
thrust force diminishes.
Dip switch
1 on: when the gate has opened, it closes automatically after the time established through the
T.C.A. trimmer;
off: the closing manoeuvre requires a manual command;
2 on: when the automation is operational, a sequence of opening/closing commands causes the
gate to OPEN-CLOSE-OPEN-CLOSE etc.
off: under the same circumstances, the same sequence of commands causes the gate to OPEN-
STOP-CLOSE-STOP-OPEN-STOP, etc. (step-by-step function) (see also dip switch 4);
3 on: during the opening phase, the photocell cuts in, stopping the gate until the detected obstacle
has been removed. During the closing phase, it causes the gate to stop and then to open again
all the way;
off: during the opening phase the photocell does not cut in, while during the closing phase it
behaves in the same way as it does when in the ON mode;
4 on: the gate behaves as established by dip switch no. 2
off: the gate ignores the closing commands during the opening manoeuvre;
5 on: the pre-flashing function is enabled;
off: the pre-flashing function is disabled;
6 on: the "photocell test" function is enabled;
off: the "photocell test" function is disabled. N.B.: to be used when the photocells are not used;
7 on: following the connection of the photocell contact (input 10 - 11), the gate closes automatically
after 5 seconds;
off: function disconnected;
LOGIC ADJUSTMENTS

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis