Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Characteristics - tau K123M Installationsanleitung

Schalt- und steuertafel fur den getriebemotor master 12q
Vorschau ausblenden Andere Handbücher für K123M:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 20
LOGICS WITH MICROPROCESSOR
STATUS OF INPUTS SIGNALLED BY LEDs
"PEDESTRIAN GATE" FUNCTION
INCORPORATED FLASHING CIRCUIT
ENCODER SENSOR FOR OBSTACLE DETECTION AND SELF-LEARNING OF TRAVEL
RECEIVER CONNECTOR
BATTERY CONNECTOR
BATTERY CHARGER BOARD (INTEGRATED)
DIAGNOSTICS OF MALFUNCTIONS SIGNALLED BY LED
When you have completed the connection:
All the green LS LEDs must be on (each of them corresponds to a Normally Closed input). The
go off only when the controls to which they are associated are operated.
All the red LS LEDs must be off (each of them corresponds to a Normally Open input). The light
up only when the controls to which they are associated are operated.
Before proceeding, make sure the mechanical components work correctly. Also check that
the gear motor assembly has been installed according to the instructions. Then make sure
that the power consumption of the gear motor is not greater than 3A (otherwise the control
panel may not work properly).
THE EQUIPMENT MUST BE INSTALLED "EXPERTLY" BY QUALIFIED PERSONNEL AS
REQUIRED BY LAW.
NB : it is compulsory to earth the system and to observe the safety regulations that are in
force in each country.
IF THESE ABOVE INSTRUCTIONS ARE NOT FOLLOWED IT COULD PREJUDICE THE
PROPER WORKING ORDER OF THE EQUIPMENT AND CREATE HAZARDOUS SITUATIONS
FOR PEOPLE. FOR THIS REASON THE "MANUFACTURER" DECLINES ALL RESPONSIBILITY
FOR ANY MALFUNCTIONING AND DAMAGES THUS RESULTING.
Board power supply
Max motor power DC
Fast acting fuse for protection of input power supply 13.5 Vac (F1 - 5x20)
Fast acting fuse for motor protection (F2 - 5x20)
Fast acting fuse for protection of auxiliary circuits 18 V dc (F3 - 5x20)
Fast acting fuse for protection of battery (F4 - 5x20)
Motor power supply circuits voltage
Auxiliary device circuits supply voltage
Logic circuits supply voltages
Operating temperature
CONTROL BOARD FOR MASTER12Q GEARMOTOR

TECHNICAL CHARACTERISTICS

English
TESTING
INSTALLATION
13,5 Vac - 50 Hz
50 W - 18 Vdc
F 15A
F 15A
F 1,6A
F 10A
18 Vdc
18 Vdc
5 Vdc
-20 °C ÷ +70 °C