ozonization
The function of ozonation is in the hydromassage bath-tubs started automatically with aggregate starting and rele-
asing of air regulators. In the equipment designed for hydromassage bath-tubs the ozone is produced in a silent
electrical discharge from the oxygen present in the air. This way of ozone creation is not demanding as to the ener-
gy and very effective. The application of silent electrical discharge is much more effective and economically more
advantageous than using of UV radiation sources and it is also not necessary to replace any consumable materi-
al during the equipment service life. Ozone is the most effective disinfection and oxydation agent which destroys
the pathogenic organisms very quickly. Ozone helps to disinfect the tubing through which the water passes and which is
not accessible for mechanical cleaning. Ozone application makes the bathing in the massage bath tub much more safety
and healthy. Even low concentrations of ozone in the water have the favourable therapeutic effect, the skin is well perfused,
have anti-bacterial, anti-virus and anti-fungal effects. Nevertheless at safety dosing applied they cannot totally replace
the disinfection performed in the scope of bath-tub maintenance.
11.Passive hygiene
Into the filled bath-tub pour the cleaning or disinfection solution (concentration according to the producer's recommenda-
tion). Start the hydromassage and whirlpool massage for about 10 – 15 minutes. Take care that nobody uses such bath for
bathing. After the massage is completed, let the water stay in the bath tub for 1 – 3 hours and start it again for about 3 minu-
tes. Drain the water. Fill the bath tub with clean cold water and start the hydromassage and whirlpool system for 1 – 3 minu-
tes. After the hydroairmassage stops, drain the water, wash down, dry with wet cloth or a sponge. For cleaning the surface
we recommend common available cleaning liquid means which do not contain abrasives (sand particles) which could cause
scratches of acrylate surface and components. It is recommended to perform the passive maintenance once a month.
12. bath additives
During massage it is possible to use all kinds of herbal additives but without rough parts of etheric oils. These are especially
needle-leaved, eucalyptus, tannin, fruit, camomile, tarragon, nettle, agrimony, etc. baths. During usage of hydromassage
system do not use the bath foam as this may easily aerate the pump and worsen the hydromassage function. If you use
various soaps, additives , bath salts etc., perform the effective hygiene and disinfection of the bath tub after each bath.
13. d ocumentation
When purchasing the bath-tub, check whether you have received all documentation!
user's manual, properly executed certificate of Warranty , instruction for construction readiness!
Take care that the seller fills thoroughly the Certificate of Warranty. Nevertheless, if there are unauthorised interventions
found or it was operated not in compliance with instructions shown in the Manual, the claim shall not be accepted. The
producer also does not bear responsibility for the damage and injury caused by improper inside house installation and for
the non-correct connection or usage.
14. defects and their remedy
defect
The system cannot be started
The required procedure
cannot be started
Halogen light does not work
Water quantity in bath lessens
Maxi nozzle does not work
Not movable nozzles
Malodorous system
Lower effect of massage
- general maintenance of hydrotherapeutic bath-tubs
to hydrotherapeutic bath-tubs
cause
-circuit breaker is off
- bad electrical installation
- small quantity of water (at el. water)
- loose tube (at pneum. control)
- sharp change of procedures
- defective lamp
- mechanical outlet is not adjusted
- the nozzle is totally closed
- the nozzles are clogged with the scale
- effective maintenance not performed
- system clogged with scale
remedy
- start the circuit breaker
- check the house installation
- add more water
- insert the air tube to the pneu switch
- change procedures
not earlier than after 5 sec
- change the halogen lamp
- sadjust the screw at plug switch
- open the nozzle by turning
- see the maintenance
- see the maintenance
- see the maintenance
25