setting of water temperature
Switch off the hydromassage and the sparkling bath. Press the button
depressing the button
The regulation range is from 15°C to 55°C (according to the volume of water fi lled). The recommended water temperature,
i.e. the Hyper-thermal bath is from 37°C to 40°C.
starting heating
By depressing the
button, the heating is activated. Its switching on is signalised by lighting of the red control lamp at the
top on the left, this only in a case that the water has lower temperature than the preset one. If the water temperature in
the bath is higher than the preset, the heating will not start and the control lamp will not light. This does not mean that the
heating is switched off, but it is active and starts in case the water temperature drops below the preset value. The heating
is working only with hydromassage running. By repeated depressing the button
cold water is time consuming, the heating is aimed for additional heating of water !!!
disinfection - fl ushing
After the water is drained from the hydromassage bath tub by pressing the button (desinfection) the process of fl ushing and
disinfection is activated. The electromagnetic valve is opened automatically (upon leading to the injector and sucking on the
desinfection – 5 seconds). After 5 seconds also the second electromagnetic valve with clean water opens automatically.
The disinfection agent and clean water are mixed in the mixer and fl ows further into the distribution tubing of hydromassage
(25 seconds). The distribution tubing of disinfection solution is designed so as to fl ush entire tubing. After then the interval
follows in which the disinfection solution reacts inside the distribution tubing and hydromassage components (60 seconds).
After one minute's reaction the electromagnetic valve opens again and the tubing is fl ushed with clean water (40 seconds).
At the systems with airmassage the 60 seconds interval follows for the water to fl ow off into the drainage tubing. After one
minute the compressor starts automatically and dries up the distribution tubing of the airmassage.
the disinfection system can be started even before starting the massage !!
halogen lighting
By pressing the
button the halogen lighting goes on. By repeated pressing the
hydromassage bath
The hydromassage bath is switched on by pressing the
bath is switched off. The intensity of hydromassage bath can be set by interrupted pressing the
sing the
button at the hydromassage bath running, the cycling is switched on (the hydromassage bath is switched on
and off in regular intervals). By repeated pressing the
(LUX system ) bath tubs have the „Water pressure zoning" installed. By means of three-way valve and its positions I, II, III we
can prefer the activity of individual nozzle sections or to select the individual massages.
9. eXcellent duo
which is positioned on the upper edge of the bath.
- electronic controller
- hydromassage
hydromassage / airmassage – on / off
hydromassage intensity regulation
hydromassage cycling
system of water pressure regulation by means of nozzle
By rotating the nozzle to the right the water fl ow is regulated to minimum, by rotating to the left the
maximum water fl ows attained.The nozzle's body can be set directionally. After the bath tub is
connected to the power source, the real time is displayed in the form of hours and minutes.
clock setting
At the fi rst pressing of button
(see the fi g.) This blinking signalises the possibility to set the units and tens of hours by means of buttons
the second pressing of button
(see fi g.) This blinking signalises the possibility to set the units and tens of minutes by means of buttons
third pressing of button
which fi nishes setting of the clock. In case of power supply blackout, the clock is supplied from the battery which is a part
of the control.
you will receive the possibility to change the required value by means of the
the colon stops blinking in the rhythm of seconds and tens and units of hours are blinking
the tens and units of hours stop blinking and the tens and units of minutes are blinking
the tens and units of minutes stop blinking and the colon is blinking in the rhythm of seconds,
, the display will show the water temperature. By
the heating is switched off. Warming of
button. By repeated pressing the
button the cycling is switched off. The Apollonia, Antalie, Athina
Three-way valve
Switching on and off is performed by electronic controller
system – on / off
disinfection
lighting – on / off
and
button the lighting goes off.
button the hydromassage
and
buttons. By pres-
I.
- foot nozzles
II.
- all nozzles
III. - back nozzles
water heating
temperature thermometer
day time
and . At the
buttons.
and
. At