Herunterladen Inhalt Inhalt Diese Seite drucken

TEIKO BASIC Benutzeranleitung Seite 23

Hydromassagewannen
Vorschau ausblenden Andere Handbücher für BASIC:
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

switching on and function setting
By depressing the button
control of bath functions is switched off. If the bath is fi lled with water, the switching on is signalised by lighting of a green
signal light at the top of the button
mentioned functions are not accessible. The display shows 00:00 (minutes, seconds) as the starting status for counting of
time which signalises the time of usage of hydromassage or sparkling bath.
in this position the following functions are active :
setting of massage time
By means of the button
time setting after one minute can be performed by buttons
counted from time set in this manner during usage of hydromassage or sparkling bath. When it reaches the zero position,
the massage cycle is switched off automatically.
display of water temperature
By depressing the
in the bath and after 3 seconds the display automatically shows again the counted, respectively counted off time. If neither
the hydromassage nor the sparkling bath are running, the display after depressing the button
water temperature.
setting of water temperature
Switch off the hydromassage and the sparkling bath. Press the button
depressing the button
The regulation range is from 15°C to 55°C (according to the volume of water fi lled). The recommended water temperature,
i.e. the Hyper-thermal bath is from 37°C to 40°C.
starting the heating
By depressing the
top on the left, this only in a case that the water has lower temperature than the preset one. If the water temperature in
the bath is higher than the preset, the heating will not start and the control lamp will not light. This does not mean that the
heating is switched off, but it is active and starts in case the water temperature drops below the preset value. The heating
is working only with hydromassage running. By repeated depressing the button
cold water is time consuming, the heating is aimed for additional heating of water !!!
disinfection - fl ushing
After the water is drained from the hydromassage bath tub by pressing the button (desinfection) the process of fl ushing
and disinfection is activated. The electromagnetic valve is opened automatically (upon leading to the injector and sucking
on the desinfection – 5 seconds). After 5 seconds also the second electromagnetic valve with clean water opens auto-
matically. The disinfection agent and clean water are mixed in the mixer and fl ows further into the distribution tubing of
hydromassage (25 seconds). The distribution tubing of disinfection solution is designed so as to fl ush entire tubing. After
then the interval follows in which the disinfection solution reacts inside the distribution tubing and hydromassage compo-
nents (60 seconds). After one minute's reaction the electromagnetic valve opens again and the tubing is fl ushed with clean
water (40 seconds).
At the systems with airmassage the 60 seconds interval follows for the water to fl ow off into the drainage tubing. After one
minute the compressor starts automatically and dries up the distribution tubing of the airmassage.
the disinfection system can be started even before starting the massage !!
halogen lighting
by pressing the
hydromassage bath
The hydromassage bath is switched on by pressing the
bath is switched off. The intensity of hydromassage bath can be set by interrupted pressing the
pressing the
button at the hydromassage bath running, the cycling is switched on (the hydromassage bath is switched
on and off in regular intervals). By repeated pressing the
sparkling bath
By depressing the
switches off. The intensity of sparkling bath can be set by interrupted pressing of buttons
button during running of the sparkling bath, the cycling will switch on, the intensity of sparkling bath ranges automatically
from minimum value to the value set by the
cycling will switch off. The Apollonia, Antalie, Athina (LUX system ) bath tubs have the „Water pressure zoning" installed.
cycling will switch off. The Apollonia, Antalie, Athina (LUX system ) bath tubs have the „Water pressure zoning" installed.
By means of three-way valve and its positions I, II, III we can prefer the activity
of individual nozzle sections or to select the individual massages.
23
the control of bath functions is switched on. After repeated depressing of the same button, the
, if there is not a suffi cient quantity of water, the signal light is blinking and the below
the time 05,00 10,00 and 15,00 minutes for automatic switching off can be selected. The fi ner
button the display, during running of hydromassage or sparkling bath, will show the water temperature
you will receive the possibility to change the required value by means of the
button, the heating is activated. Its switching on is signalised by lighting of the red control lamp at the
button the halogen lighting goes on. By repeated pressing the
button the sparkling bath activates. By repeated depressing of the
and
in the lower and upper row of buttons. The time is
button. By repeated pressing the
button the cycling is switched off.
and
buttons and backward. By repeated depressing of the
Three-way valve
shows permanently the
, the display will show the water temperature. By
the heating is switched off. Warming of
button the lighting goes off.
button the hydromassage
button the sparkling bath
and
and
buttons.
and
buttons. By
. By depressing the
button the
I.
- foot nozzles
II.
- all nozzles
III. - back nozzles
Inhaltsverzeichnis