Herunterladen Inhalt Inhalt Diese Seite drucken

Specifications; Operating Conditions - Axis Q6042-C PTZ Installationshandbuch

Vorschau ausblenden Andere Handbücher für Q6042-C PTZ:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 71
Function
Pin – wire
Configurable
2 – blue
(Input or
7 – yellow
Output)
RX+
3 – green/white
4 – green
RX-
TX+
5 – orange/white
6 – orange
TX-
8 – black
0 V DC (-)
DC output
1, 9 – red
(12 V)

Specifications

Operating Conditions

The Axis product is intended for outdoor use.
Classification
AXIS Q6042-C
AXIS Q6044-C
AXIS Q6045-C Mk II
Notes
Digital input – Connect to pin
8 to activate, or leave floating
(unconnected) to deactivate.
Digital output – Connected to
pin 1 when activated, floating
(unconnected) when deactivated. If
used with an inductive load, e.g. a
relay, a diode must be connected in
parallel with the load, for protection
against voltage transients.
Ethernet – receiving
Ethernet – receiving
Ethernet – transmitting
Ethernet – transmitting
Used to power camera
IEC 60721-3-4 Class 4K4H, 4M4
IEC 60529 IP66
NEMA 250 Type 4x
MIL-STD 810G 500.5, 501.5, 502.5, 503.5, 505.5, 506.5,
1
507.5, 509.5, 510.5
, 514.6
19
AXIS Q60 Series
Specifications
0 to max 30 V DC
0 to max 30 V DC,
open drain,
100 mA
0 V DC
12–13.2 V DC

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Q6045-c mk ii ptzQ60 seriesQ6044-c ptz