Special accessories
PWA2700
Note: An embrasure breadth of at least 88 cm is required for embedding into the wall on
both sides.
• When using the PWA2700, first loosen the screws on the rear of the door bar and remove
the door bar end piece (Fig. 25).
• Insert the door bar end piece with round bolts and tighten with the screw (Fig. 26).
• Mount the wall strike plate onto the round bolts.
• Lock the door bar onto the wall until the end stop. Mark out the attachment point (1.) of
the wall strike plate. Close back the door bar (Fig. 28).
• Pre-drill the attachment points for the wall strike plate with Ø 6 mm, insert the dowel
and screw (Fig. 28).
• Drill through both of the external mounting holes (2.) with Ø 10 mm, and a depth of at
least 140 mm. Insert the complete dowel with the screw and tighten (Fig. 28).
• Drill out the holes for the connecting bolts (3.) with Ø 14–16 mm, with a depth of 70 mm
(Fig. 28). Press down the plastic cover.
Fig. 25
2.
Fig. 27
86
Fig. 26
1.
1.
Fig. 28
2.
1.
3.
3.
2.
1.
Fig. 29
Fig. 30
2.
Fig. 31
PSB2700
T-catch unit to open the door a crack in the
secured state. See also the fitting instructions
for PSB2700.
PV1820
Fixing set with all-through screw fitting to
attach the lock cases onto the door frames or
on the wall (Fig. 30).
It is used if the lock cases cannot be mounted
to the door frames or wall in a stable manner.
The outer cover is visible, use one PV1820
per lock case.
Drill through the mounting holes of the lock
cases with Ø 8–9 mm, drill out Ø 13–15 mm and
a depth of 35–40 mm from outside and screw
the lock case (Fig. 30).
PA1018
Fixing set for doors that open outward
(Minimum width of door leaf 790 mm, fig. 31).
The fixing set PA1018 is absolutely essential for
a door that opens outward. It involves an all-
through screw fitting, where the reinforced door
bar is firmly fixed to the door panel. The fitting
takes place according to the illustration.
Use longer screws for door panel thicknesses
exceeding 80 mm (strength of at least 8.8).
With fixed lock bodies using the existing
mounting locks that are accessible depending
on the door bar's position, drill through Ø 8,5
mm, drill out Ø 13 mm and a depth of 35 mm
and screw (Fig. 31).
Note: The fixing set can also be fixed horizon-
tally if necessary.
87