Herunterladen Inhalt Inhalt Diese Seite drucken

General Information - Abus PR2800 Montage- Und Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für PR2800:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Individual parts (Fig. 1)
1
2
1 x
Reinforced door bar
for the lock body
4
5
2 x
Screw-on plate
Plastic underlay
7
8
2 x
Cover
Cylinder escutcheon
for the outside
for the lock cases
10
11
4 x
Dowel Ø 6 mm
Dowel Ø 10 x 120 mm
13
14
8 x
Screw Ø 4 x 35 mm
Screw Ø 4.2 x 22 mm
16
17
4 x
Hexagon socket head screw
Cover for the hole in the wall
M8 x 60 mm
76
3
1 x
2 x
Cover
End piece for the cover
6
3 x
2 x
Lock case
9
1 x
4 x
Bridging cartridge Ø 6 mm
12
4 x
4 x
Screw Ø 3.5 x 6.5 mm
15
8 x
4 x
Wooden screw Ø 7 x 60 mm
18
1 x
1 x
Door cylinder (optional)
II. General information
The ABUS reinforced door bar provides additional protection against unauthorised break-
ins into rooms. It is suitable for all standard doors made of wood, metal and plastic. Not
all varieties of use for the PR2800 can be addressed with these fitting instructions. Ask a
dealer if necessary.
The optimal protective effect is reached if you proceed according to these fitting and
operating instructions. The mounting screws should be tightened manually with a suitable
tool to avoid overwinding. Prior to fitting, you should ensure that the reinforced door bar is
suitable for the structural circumstances.The manufacturer disclaims all liability for any
injury or damage caused during fitting and/or by improper handling!
At least one main access must be able to be operated from the outside as intended.
We recommend allowing a specially trained specialist installer to execute the fitting.
III. Field of application of the PR2800
The PR2800 is suitable for all hinged and unhinged doors that open inwards and outwards,
DIN right or DIN left (Fig. 2). Doors with panelling and/or border trimmings must be
individually adjusted (use lock underlays if necessary).
The standard design is suitable for doors opening inwards (door panel width of length 1:
735 mm to 980 mm or length 2: 980 to 1200 mm and door panel thicknesses of 33 to
48 mm). Use spacer discs DS10 from a door panel thickness of 48 mm.
The PR2800 can be fitted with a knob cylinder or a door half-cylinder
(without the possibility of closing from the outside).
The PR2800 can also be equipped with different door cylinders following EN DIN 1303 /
DIN 18252. The proper functioning of the integrated protection to prevent the bolt from
being pushed back is only guaranteed when using a double profile cylinder without
rotating cam with the key removed.
We recommend fitting beneath the mounting (Fig. 3).
The fitting of 2 pieces PR2800 is recommended in the event of increased safety
requirements. One is then fitted above and below the mounting (Fig. 4).
GB