Herunterladen Inhalt Inhalt Diese Seite drucken

Petsafe Staywell 400 series Montageanleitung Seite 5

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 42
b) In PVC/uPVC/Metal
**
'Magnetic' cat fl aps will not work if installed directly into a surface
containing metal. The unit must be isolated from these materials in a
wooden frame (not provided).
Using the horizontal line as a base, draw a square with minimum
dimensions of 306 mm x 306 mm (This will be the external dimensions of
your wooden frame).
Cut out the square with a jig or keyhole saw. Fit a wooden frame to the
hole with internal dimensions of 175 mm x 168 mm. The enclosed cutting
template can be used to ensure an accurate cut out.
It is within the wooden frame that your cat fl ap should be fi tted to ensure
that is fully isolated from any metal (Fig. 4).
306 mm
168 mm
175 mm
306 mm
FIG.4
Wooden frame
PVC/uPVC/Metal**
306 mm
168 mm
175 mm
306 mm
PVC/uPVC/Metal door
Replacement fl aps available online
c) In Glass
Glass windows & doors, single and double glazed*
* It is not possible to cut holes in toughened glass or double glazed
units except at the time of manufacture. If fi tting a 'Magnetic' model into
double glazed glass a plastic spacer bar must be used. Please consult
a glazier.
The cat fl ap requires a circular hole with diameter of 212 mm (Fig .5).
FIG.5
212 mm
Not to scale - for best results you should refer
your glazier to the enclosed cutting template.
d) In Walls
Fits brick walls
Follow the instructions for "Wood", by using the enclosed cutting
template. Please note that additional tools, materials and competent DIY
skills may be required.
5

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis