Introduction

2.2. Technical Specifications

Connection type:
Power supply
Coil tension:
Coil current:
Additional power supply:
Terminal:
Recognised caller signal:
Recognised busy signal:
Recognised busy signal interval: Signal tones for 160-700 ms or pauses for 160-700 ms respectively.
Dialling methods:
Built-in relay:
Relay switch power:
Memory:
Tested according to:
42
Analogue telephone line, a/b port
Via the a/b port
20-70 VDC
20-60 mA
12 V = potential-free +/- 3 V, max. 1200 mA
Behnke power supply unit or any other additional power supply
in connection with a Behnke DC-DC converter; an individual power
supply unit is needed for every Behnke intercom station.
ZR according to TBR 21
cannot be specified exactly, as it depends on the signal's
amplitude, frequency and interval
300-500 Hz sinus
DTMF dialling, 50/50 ms (tone/pause)
One piece (one switch relay)
max. 60 VA/24 W: 0.5 A, 120 V~/1 , 24 =(load)
EEprom, non-volatile
TBR 21 as well as EC 201 121 (EU-wide network access)
EN 55022, EN 55024 (Electromagnetic Compatibility)
EN 60950 (product safety)