Strictly observe the minimum distance between hood and hob.
Clean the surrounding of the installation area before you install the appliance so
the appliance will not extract any dust or construction waste.
The exhaust hose must not run in the same exhaust duct as gas tubes, hot air
tubes et cetera.
Lead away the exhaust hose from the hood as straight as possible.
The proper maximum bending angle outwards is 120
Check with a level if the appliance is horizontally positioned while installing and
after having installed it.
1. The ceiling must take a weight of at least 120 kg. The ceiling gauge must be at
least 30 mm.
2. Drill a hole with a diameter of 170 mm through the ceiling.
3. Drill 12 holes which have to met the dimension of the suspension device into
the ceiling (fig. 1).
4. Fix the suspension device with 12 big flathead screws type ST6*40 mm on the
ceiling. Take 8 dowel screws when fixing on a concrete ceiling.
Installation of the hood
27
.
0