Identifying and eliminating faults
Fault
The condensate
does not
drain off
Alarm is triggered.
Condensate drains
off but alarm is
activated.
Compressed air per-
manently escaping.
Accessories
Order No.
EHT-ED4100-G230
EHT-ED4100-N115
MK/50-G15-G15
MK/50-G08-G15

Spare parts

Order No.
SKED4100/50
RKED4100/50
24
Possible cause
• Shut-off valve upstream of conden-
sate drain closed.
• The internal dirt trap is clogged.
• The valve does not open /
valve seat is soiled.
• The line at the condensate outlet is
clogged.
• The condensate drain is not installed
correctly:
- Air bubbles trapped in the con-
densate drain block the line.
- Vent line missing or is shut off.
• Power supply interrupted
• The cleaning operation is not suffici-
ent to enable complete emptying.
• The valve is defective.
• Electronics/coil defective
(overvoltage/short-circuit)
• The valve does not close.
Description
Heater, PN30, G1/2, 230VAC
Heater, PN30, NPT1/2, 115VAC
Ball valve, including screw fitting (G1/2 to G1/2, PN50)
Ball valve, including screw fitting (G1/4 to G1/2, PN50)
Description
Dirt trap, seals, for housing and electronics module
Solenoid valve, seals, for housing and electronics module
Remedy
• Open shut/off valve at conden-
sate inlet and/or in vent line.
• Clean internal dirt trap.
• Open valve manually, clean
valve seat and replace if ne-
cessary.
• Clear blockage in condensate
outlet.
• Install vent line or open shut-off
valve in vent line.
• Reconnect the unit to the pow-
er supply.
• Clean condensate drain.
• Replace valve.
• Renew coil or replace conden-
sate drain if necessary.
• Clean valve seat, replace valve
if necessary.
ED4100/50_01