4 Operation

Information on the
identification plate
Serial number

3.3 CE label

The CE label shows that the products
comply with the basic requirements of the
applicable directives as stated on the iden-
tification plate.
The declaration of conformity can be
viewed at the manufacturer's site.
4 Operation

4.1 Switching on the product

Applicability: VAR 60/1 D
Use the VAZ RC remote control to
initialise all of the ventilation units in
the system one after the other.
– See the operating instructions for
the remote control.
Note
When using an optional VAZ
CPC control, the remote con-
trol is only required for the
start-up.
Starting with the master, use the
on/off switch to switch on all of the
ventilation units in the ventilation sys-
tem in sequence. If an optional VAZ
CPC control is provided, start this up
before switching on the master.
Use the VAZ CPC control or the
VAZ RC remote control to set an
operating mode and the functions.
28
Meaning
The 7th to 16th digits
of the serial number
form the article num-
ber
– See the operating instructions for
the control or for the remote con-
trol.
Applicability: VAR 60/1 DW
Use the VAZ RCW remote control to
set up all of the ventilation units in the
system as either masters or slaves.
– See the operating instructions for
the remote control.
Use the on/off switch to switch on all
of the ventilation units in the ventila-
tion system. If an optional VAZ CPCW
control is provided, this must be con-
figured as the master.
Use the VAZ CPCW control or the
VAZ RCW remote control to set an
operating mode and the functions.
– See the operating instructions for
the control or for the remote con-
trol.

5 Troubleshooting

Conditions: Ventilation units do not work
Switch off the product.
Check whether the fan unit has been
installed correctly on the wall-mounting
frame.
Check whether the contact for the plug
connection has been correctly estab-
lished.
Conditions: Strong wind, Ventilation not possible
Switch the product to eco mode.

6 Care and maintenance

Danger!
Risk of death from electric
shock
Switch off the product using
the on/off switch.
Disconnect the product from
the power supply by switch-
Operating instructions recoVAIR 0020236695_02