In order to be able to determine which input, if any, has been triggered, a special
function has been built in which, after deactivation of the alarm,
can determine which sensor input has been triggered. This takes place as follows:
Deactivate the alarm, if it has been triggered 4 tones will be heard and the
hazard lights will flash 4 times
The dashboard LED will flash rapidly to indicate automatic reset after 60
seconds.
Open the door or start up to interrupt the reset.
Depending on what the cause was, the dashboard LED and the internal siren
will:
Switch on and off once if a direct sensor alarm has been activated.
Switch on and off twice if a delayed sensor alarm has been activated.
Switch on and off 3 times if the voltage drop detector has been activated.