Herunterladen Inhalt Inhalt Diese Seite drucken

Inocal PROMATIC CMP25-2 Bedienungsanleitung Seite 29

Witterungsgeführte heizungsregler des mischerheizkreises
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Basic settings
Parameter
Function
AUT. SWITCHOVER
P1.1
SUMMER/WINTER
P1.2
AVERAGE OUTDOOR
TEMP. FOR SUMMER/
WINTER SWITCHOVER
REQUESTED ROOM
P1.4
TEMPERAT. BY FROST
PROTECTION
P1.5
TEMPERATURE ROUND
UP
P1.6
AUT. SHIFT OF CLOCK
TO SUMMER/WINTER
TIME
PERIOD OF TEMPERAT.
P1.7
LOGGING (MINUTES)
P1.8
TONES
P1.9
ADVANCED
TEMPERATURE SCREEN
Settings for heating circuit
Parameter
Function
P2.1
HEAT CURVE
STEEPNESS
:
Parameter description
Automatic switch-off of heating in accordance to average
one-day outdoor temperature.
Setting of average one-day outdoor temperature at which
the heating should switch-off.
Setting of room temperature when heating is switched off.
You set the accuracy of displayed temperatures.
With the help of a calendar, the controller carries out the
automatic changeover between summer and winter time.
By setting this field you define how often the measured
temperatures are saved.
By setting this field you define sound signals of the con-
troller.
Advanced screen means that while checking temperatu-
res you can see measured and required or calculated
temperature.
:
Parameter description
Heating curve steepness tells us, what temperature is
required for the heating bodies by a determined outdoor
temperature. The steepness setting depends on the type
of heating system (floor, wall, radiator, convector heating)
and insulation of the building.
29
Default
Setting range
value
0- NO
0
1- YES
10 ÷ 30 °C
18
2 ÷ 12
6
0- 0.1 °C
1- 0.2 °C
2
2- 0.5 °C
3- 1 °C
0- NO
1
1- YES
5
1 ÷ 30 min
0- OFF
1
1- KEYPAD
0- NO
1
1- YES
Default
Setting range
value
0,7 - floor
1,0 - radia-
0,2 ÷ 2,2
tors
Service settings manual

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis