INSTALLATION

Safety

INSTALLATION
6.
Safety
Only a qualified contractor should carry out installation, commis-
sioning, maintenance and repair of the appliance.
6.1

General safety instructions

We guarantee trouble-free function and operational reliability only
if original accessories and spare parts intended for the appliance
are used.
6.2

Instructions, standards and regulations

Note
Observe all applicable national and regional regulations
and instructions.
7.

Appliance description

The open vented (non-pressurised) appliance is suitable only for
oversink installation. The appliance is intended to heat cold water
and supply it to a single draw-off point.
The appliance must only be installed with an open (non-pres-
surised) tap.
7.1

Standard delivery

Delivered with the appliance are the following:
- Wall mounting bracket
7.2

Required accessories

Select an open (non-pressurised) tap that is appropriate for your
requirements and equipment:
Twin-handle mixer tap
- WKM
Mono lever mixer tap
- MEK
8.

Preparations

f Flush the water line thoroughly.
f
Water installation
A safety valve is not required.
Taps/valves
Sealed unvented taps are not permitted.
f Install an open vented tap.
f
www.stiebel-eltron.com
8.1

Installation site

Material losses
!
Install the appliance in a room free from the risk of frost.
Material losses
!
Mount the appliance on the wall. The wall must have a
sufficient load-bearing capacity.
Material losses
!
Connecting hose length (from tap to appliance) may not
exceed 1 m.
For connecting hoses > 1 m:
f Install a tube aerator attachment in the overflow
f
line.
Note
The appliance is only suitable for oversink installation.
The water connections of the appliance point downwards.
Note
Ensure that the appliance is freely accessible for main-
tenance work.
Always install the appliance vertically and near the draw-off point.
9.
Installation
9.1

Appliance installation

f Mark out the holes to be drilled on the wall (see chapter "In-
f
stallation / Specification / Dimensions and connections").
f Drill the holes and insert suitable rawl plugs.
f
f Secure the wall mounting bracket using suitable screws.
f
f Hang the appliance on the wall mounting bracket.
f
Note
Surplus cable can be stored in the cable compartment.