Herunterladen Inhalt Inhalt Diese Seite drucken

Abicor Binzel SR/ABITIG GRIP Betriebsanleitung Seite 18

Vorschau ausblenden Andere Handbücher für SR/ABITIG GRIP:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3 Product description
Type
Type of
cooling
®
SR/ABITIG
GRIP
24 G
air
24 W
liquid
®
ABITIG
GRIP
12-1
liquid
18 SC
liquid
®
SR/ABITIG
GRIP
9
air
17
air
26
air
18
liquid
20
liquid
20 SC
liquid
SR (handle tube)
20
liquid
Tab. 4
Product-specific torch data (EN 60 974-7)
*According to EN 60 974-7 the value for alternating current (AC) must be given at 70% of the tested direct
current value (DC).
Liquid-cooled torches
Tab. 5
Required cooling unit capacity
All data refer to 4 m hose assemblies. For any further information regarding the available hose
assembly designs and performance data, please refer to the order documentation.
EN - 6
Load
ED
Electrode ø
DC
AC*
A
A
%
mm
110
80
35
0,5 - 1,6
140
100
100
0,5 - 2,4
400
280
100
1,6 - 4,0
400
280
100
0,5 - 4,8
110
80
35
0,5 - 1,6
140
100
35
0,5 - 2,4
180
130
35
0,5 - 4,0
320
230
100
0,5 - 4,0
240
170
100
0,5 - 3,2
320
220
100
0,5 - 3,2
220
150
100
0,5 - 3,2
min. 800 W
SR/ABITIG
Gas
Cooling
flow
Max.
Min.
supply
flow
temp.
l/min
°C
l/min
5 - 12
7 - 15
50
0.7
7 - 20
50
0.8
7 - 20
50
0.8
5 - 12
7 - 15
7 - 18
7 - 20
50
0.8
8 - 20
50
0.7
8 - 20
50
0.7
8 - 20
50
0.7
BAL.0047 • 2018-09-11
®
GRIP
Torch inlet
pressure
min.
max.
bar
bar
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis