Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Spare Parts And Accessories - Aventics EV03 Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
AVENTICS | EV03 | R414008223–BAL–001–AA | English

13 Technical Data

Table 15:
General data
General data
Dimensions for the EV03
50 mm x 72 mm x 100 mm
with base plate
(width x height x depth)
Weight
EV03 with base plate: 260–335 g
Depending on the configuration, see the AVENTICS
online catalog
–10 °C to 60 °C
Operating temperature
range
–25 °C to 80 °C
Storage temperature
range
Ambient operating
Max. height above sea level: 2000 m
conditions
Version
Externally piloted pressure regulator
Permissible medium
Compressed air
Pneumatic connections on
G 1/4
the base plate
Max. particle size
40 μm
Oil content of compressed
0–5 mg/m
air
The pressure dew point must be at least 15 °C below the ambient and medium
temperatures and must not exceed 3 °C.
The oil content of compressed air must remain constant during the life cycle.
O Use only the approved oils from AVENTICS, see the AVENTICS online catalog,
chapter "Technical information".
Mounting orientation
Any if used with dry and oil-free compressed air
Protection class according
IP65 (only when assembled and with all plugs
to EN 60529/IEC 60529
connected)
Relative humidity
95%, non condensing
Degree of contamination
2
Use
Only in closed rooms
Table 16:
Pneumatic data
Pneumatics
Flow rate values of the EV03 pressure regulator
p
[bar]
p
[bar]
v
1
11
10
11
10
7
6
7
6
Flow characteristic curve of the EV03 single pressure control
11
10
9
8
7
6
5
4
3
2
1
0
500
Table 16:
Pneumatic data
Pneumatics
Reproducibility
Version: "Classic": < 0.18 bar
Version: "Smart": < 0.04 bar
Hysteresis
Version: "Classic": < 0.2 bar
Version: "Smart": < 0.05 bar
3
p
[bar]
2
9.8
9.0
5.8
5.0
Pv = Pa + 1bar
1000
1500
2000
Flow [std l/min]
Table 17:
Electronics data
Electronics
Connections
Power supply
Max. current consumption
Permissible harmonic
content
Variant 0–10 V
Voltage input resistance (set
point)
External ohmic load (voltage
output/actual value)
Switch output
Variant 4–20 mA and 0–20 mA
Current input resistance (set
point)
External ohmic load (current
output/actual value)
Switch output
IO-Link variant
Control
IO-Link version
Baud rate
Cycle time
Operating Mode
Port type
Table 18:
Standards
Standards complied with
EN 61000-6-2
EN 61000-6-4
Q [l/min]
DIN EN ISO 4414 Pneumatic fluid power – General rules and safety
880
1370
550
1050

14 Spare Parts and Accessories

Information on spare parts and accessories can be found in the online catalog at
www.aventics.com/pneumatics-catalog.
2500
M12 connection, 5-pin, A-coded
24 V DC (+30%/−20%)
For the supply voltage, only use a power pack with
safe isolation.
120 mA to 220 mA depending on the
configuration, see the AVENTICS online catalog
5%
Power supply switched on: 1 MΩ
Power supply switched off: high-ohmic
> 10 kΩ
Voltage:
Switch output = power supply -1.8 V
Power supply switched on: 100 Ω
Power supply switched off: high-ohmic
< 300 Ω
Current:
Short-circuit-resistant, max. 1.4 A
IO-Link
1.1 (compatible with 1.0)
COM2: 38.4 kBit/s
5 ms at 38.4 kBit/s
IO-Link mode, no standard IO mode
Port class A (type A)
Electromagnetic compatibility (EMC) – Part 6-2: generic
standards – interference immunity for industrial areas
Electromagnetic compatibility (EMC) – Part 6-4: generic
standards – interference emission for industrial areas
requirements for systems and their components
22

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis