AVENTICS | AS1 / AS2 / AS3 / AS5 | R412013434–BAL–001–AG | English
Change flow direction (AS2, AS3, AS5)
No conversion is necessary on the AS1 series. The "right/
left flow" version has a separate order number.
On delivery the flow direction is from left (1, IN) to right (2, OUT).
The following conversion on the product is necessary if the flow
direction is to be changed:
Filter pressure regulator valve (FRE) conversion and
pressure regulator valve (RGS and RGP)
On all components, the flow direction change is performed by
rotating an installation by 180° around the vertical axis. The
housing cover and pressure gauge need to be replaced for the
purpose.
Change the pressure gauge and housing cover
(AS2, AS3, AS5)
6
1. Remove the mounted pressure gauge by unscrewing it from
the thread in an anti-clockwise direction.
2. Remove the blanking plug and screw it in at the other side.
3. Remove the side cover caps on the compressed air
connections by sliding a suitable tool under the cover cap
wings, carefully lifting them up and taking them off.
4. Lift the front a rear cover cap by pushing the lock-in bolts (2 on
each side) up on the latches.
5.
Remove the cover caps carefully and evenly so that
the 4 lock-in bolts do not break off.
Now lift the front and rear cap evenly by carefully levering
them open with a suitable tool and taking them off.
6. Mount the cover caps on the opposite sides in the reverse
order. The cover cap with the AVENTICS logo should be facing
to the front.
7. Screw the pressure gauge into the opposite side (see
"Mounting the pressure gauge").
8. Screw the blanking plugs into the opposite side.
Rotate the reservoir (AS2, AS3, AS5)
1. Release reservoir.
2. Rotate reservoir 180° and click it back into place.
The release is now pointing to the front.
Pressure regulator valve conversion with continuous
pressure supply
No conversion is required for pressure regulator valves
and precision pressure regulator valves RGS-DS and
RGP-DS with continuous pressure supply. On these
devices, air can be supplied from the left as well as the
right.

10 Troubleshooting

Malfunction
Pressure/flow level is not
reached or drops off
slowly.

11 Technical Data

6
Maximum permissible pressure, temperature range, and thread
connection are indicated on the products.
General data
Mounting orientation
Min./max.
medium/ambient temperature
Max. internal air consumption
Possible cause
Soiled filter
Further technical data can be found in our online catalog
at www.aventics.com/pneumatics-catalog
Remedy
Clean or
replace filter
W
Filter pressure regulator
valve: vertical
W
Pressure regulator valve:
any
W
-10 °C /+50 °C
W
RGP: 2.6 l/min
W
RGS: 1.5 l/min
10