Micropilot FMR60, FMR62, FMR67
Safety instructions:
Special conditions
Safety instructions:
Installation
Endress+Hauser
Permitted ambient temperature range at the electronics housing:
–40 °C ≤ T
≤ +80 °C
a
• Observe the information in the temperature tables.
• In the case of process connections made of polymeric material or with polymeric coatings, avoid
electrostatic charging of the plastic surfaces.
• In the event of additional or alternative special varnishing on the housing or other metal parts:
– Observe the danger of electrostatic charging and discharge.
– Do not rub surfaces with a dry cloth.
• Avoid electrostatic charging of the sensor (e.g. do not rub dry and install outside the filling flow).
Basic specification, Position 5 (Housing) = A
Avoid electrostatic charging of the housing (e.g. friction, cleaning, maintenance, strong medium
flow).
 3
1
Isolated capacitance:
with one metal plate: ≤ 3 pF (permitted in all areas for Equipment Groups II and III)
with two to three metal plates: ≤ 10 pF (not permitted in Zone 0 and for Equipment Group IIC)
2
Housing
A
2
1
1
 4
A
Zone 2
1
Potential equalization line
2
Electronic insert
3
Ex ic: Certified associated apparatus; Ex ec: Supply depending upon equipment version
4
Tank; Zone 2
5
Potential equalization
2
1
XA01551F-A
A0032146
3
4
5
A0031938