8.2 Built-in hobs

Only use the built-in hobs after you
assemble the hob into correct built-in units
and work surfaces that align to the
standards.

8.3 Connection cable

• The hob is supplied with the
connection cable.
• Replace the damaged mains cable only
with the spare parts cable. Speak to
your local Authorised Service Center.
WARNING!
All electrical connections
must be made by a qualified
electrician.
One-phase connection - 230 V~
N
L
230V~
N
L
Green - yellow
Blue and grey
Black and brown
CAUTION!
Do not drill or solder the wire
ends. This is strictly
forbidden!
CAUTION!
Do not connect the cable
without cable end sleeve.
Two-phase connection
1. Remove the cable end sleeve from
black and brown wires.
2. Remove an insulation of the brown
and black cable ends.
3. Apply a new wire end sleeve of 1.5
mm² on each cable end. (special tool
required).
Cable cross section
400V 2~N
Two-phase connection - 400 V 2 ~ N
Green - yellow
Blue and grey
Black
Brown
N
L1
L2
N
L1
L2